China's Largest One-Stop Procurement Of PLC products

SIEMENS 6ES7972-0BA42-0XA0

6ES7972-0BA42-0XA0

Nam sole orto magnitudine angusti gurgitis sed profundi a transitu arce et dum piscatorios quaerunt lenunculos vel innare

Chat Now
  • To Customize
  • Get a Sample

Take a Closer Look

  • Haec et huius modi quaedam

    Quibus ita sceleste patratis Paulus cruore perfusus reversusque ad principis castra multos coopertos paene catenis adduxit.Quibus ita sceleste patratis Paulus cruore perfusus reversusque ad principis castra multos coopertos paene catenis adduxit.

  • Haec dum oriens diu perferret, caeli reserato tepore

    Quibus ita sceleste patratis Paulus cruore perfusus reversusque ad principis castra multos coopertos paene catenis adduxit.Quibus ita sceleste patratis Paulus cruore perfusus reversusque ad principis castra multos coopertos paene catenis adduxit.

Specifications

  • Product Informations

    Two wires are inside, one red and one green, and then there is a shield on the outside. When wiring, the shield should be connected and should not come into contact with the inner wires, and you need to distinguish between incoming and outgoing wires. If it is connected in series, it is the bus of the lower line, and the substation in the middle is connected continuously. This is a very common method. For the two connectors at each end of the bus, the wires should be connected in the holes going in, not from the holes going out. The switches for both connectors should then be set to open. At this point only the incoming wires are connected and the outgoing wires are disconnected. The other intermediate connectors are set to off and their in and out wires are connected
  • Product Price

    Two wires are inside, one red and one green, and then there is a shield on the outside. When wiring, the shield should be connected and should not come into contact with the inner wires, and you need to distinguish between incoming and outgoing wires. If it is connected in series, it is the bus of the lower line, and the substation in the middle is connected continuously. This is a very common method. For the two connectors at each end of the bus, the wires should be connected in the holes going in, not from the holes going out. The switches for both connectors should then be set to open. At this point only the incoming wires are connected and the outgoing wires are disconnected. The other intermediate connectors are set to off and their in and out wires are connected
  • Delivery information

Get in Touch With Us

Experienced service team and strong production support team provide client worry-free order service.